Technical Advances |




From the Institut für Immunologie*and the Pathologisches Institut,
Ludwig-Maximilians-Universität München, München; and the Chirurgische Klinik
and the Pathologisches Institut,
Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany
| Abstract |
|---|
|
|
|---|
As a consequence, numerous protocols have been developed for the analysis of minute amounts of DNA from formalin-fixed and paraffin-embedded tissues. A challenging task is to comprehensively amplify the genomic DNA, and not only specific DNA sequences, enabling the subsequent application of various molecular genetic techniques. However, global genome amplification is particularly demanding because tissue preservation by formalin fixation and paraffin embedding negatively influences polymerase chain reaction (PCR) amplification. At present, degenerated oligonucleotide-primed-PCR (DOP-PCR)3 and primer extension preamplification4 are commonly used to perform whole genome amplification from formalin-fixed tissues. DOP-PCR rests on the use of partially degenerated primers and low stringent PCR conditions whereas primer extension preamplification uses completely degenerated primers, and consequently both methods are based on the use of thousands to millions of different primers. Each protocol has been frequently modified5-13 to various extents suggesting the existence of inherent principal problems that cannot be overcome by the modification of one or several parameters.
Recently, we introduced a novel method for whole genome amplification.14 The comprehensive amplification of genomic DNA and its sensitivity was demonstrated by the successful application of PCR products that were obtained from DNA of a single cell for comparative genomic hybridization (CGH), loss of heterozygosity studies, and DNA sequencing. Because the amplification protocol allowed single cell CGH, the method was termed SCOMP. In contrast to the DOP and primer extension preamplification techniques, only a single primer is needed, binding to a sequence that has been ligated to DNA fragments, which resulted from complete genomic digestion with the restriction enzyme MseI.
Having a method in hand for freshly prepared samples, we tested SCOMP here for the amplification of DNA isolated from archival formalin-fixed and paraffin-embedded tissues. We show that SCOMP can be applied to minute amounts of DNA from such samples and that it is superior to DOP-PCR. In addition, we investigated factors that influence the amplification success.
| Materials and Methods |
|---|
|
|
|---|
Formalin-fixed and paraffin-embedded clinical samples were obtained from the pathology departments of the University of Hamburg (center A), of the city hospital of Augsburg (center B), and of the University of Munich (center C), Germany. All investigated tumor tissues (Table 1)
were randomly selected from the archives of the three different centers.
|
Groups of three unstained cells that had been fixed in 4% buffered formalin for 20 and 40 hours, were aspirated into a glass pipette of 30-µm diameter and were transferred to a new slide. After confirming that only three cells had been transferred, these cells were finally picked in 1 µl of phosphate-buffered saline (PBS)/0.5% Igepal (Sigma, Deisenhofen, Germany) into the PCR reaction tube.
Tissue Processing
For controlled quantitative experimental conditions we isolated nuclei from tissue blocks of different ages from three nonpathological formalin-fixed and paraffin-embedded lymph nodes according to the protocol of Hyytinen and colleagues.15 After a washing step in PBS the nuclei were resuspended in PBS/0.5% Igepal and were diluted to a final concentration of 20 nuclei/µl, 60 nuclei/µl, and 160 nuclei/µl.
Laser Microdissection
Sequential 5-µm sections were cut from formalin-fixed and paraffin-embedded tissue blocks using a microtome with a disposable blade. For morphological control, one slide was stained with conventional hematoxylin and eosin staining and the sequential section was prepared for laser microdissection and mounted onto a 1.35-µm-thin polyethylene membrane (P.A.L.M. Microlaser Technologies, Bernried, Germany), attached to a glass slide. For microdissection the tissue sections were deparaffinized on a shaker, changing the xylene twice, and then incubated for 30 minutes each and were then subsequently rehydrated with a series of 100%, 85%, and 70% ethanol. To avoid interference of the nuclear staining with the amplification, slides were stained in diluted (50%) hematoxylin (Gills, Sigma, St. Louis, MO, USA) for 5 minutes. The staining was followed by a dehydrating ethanol series and the slides were dried overnight in the presence of a desiccant. For microdissection we used the P.A.L.M. Laser-Microbeam system (P.A.L.M. Microlaser Technologies). The inner side of a 200-µl tube cap was covered with 3 to 5 µl of PCR oil and the isolated cells were catapulted into the cap. The cap was subsequently mounted onto the tube and centrifuged at 14,000 x g for 5 minutes. Then 3 µl of lysis buffer [10 mmol/L Tris-acetate, pH 7.5, 10 mmol/L Mg-acetate, 50 mmol/L K-acetate (0.2 µl of 10x Pharmacia One-Phor-All-Buffer-Plus), 0.67% Tween 20 (Sigma, Deisenhofen, Germany), 0.67% Igepal (Sigma), and 1.3 mg/ml proteinase K] were added to the tube and centrifuged again for 14,000 x g for 5 minutes to separate the reaction mix from the oil.
SCOMP
After inactivation of proteinase K at 80°C for 10 minutes SCOMP was performed as described previously by Klein and colleagues14 with the exception of the adaptor-oligonucleotides (Lib1-primer: 5'-AGT GGG ATT CCT GCT GTC AGT-3'; ddMse-primer: 5'-TAA CTG ACA GCdd-3').
Probe Labeling and CGH
The labeling reaction was performed in a total volume of 40 µl consisting of 4 µl of 10x PCR buffer (Expand Long Template PCR System, Buffer 1; Roche, Mannheim, Germany), 6 µl of Lib1-primer (10 µmol/L), 1.4 µl of a dNTP stock solution (10 mmol/L for dATP, dCTP, and dGTP; 8.75 mmol/L for dTTP), 1.75 µl of 1 mmol/L digoxigenin-11-dUTP (Roche) for the test-DNA or 1.75 µl of 1 mmol/L biotin-16-dUTP (Roche) for the reference DNA, respectively, and 2.5 U of Taq-polymerase (Roche). We used 1.25 µl of the SCOMP product for reamplification and a MJ-Research PTC-200 thermocycler (Waltham, MA) was programmed to 94°C (1 minute), 60°C (30 seconds), 72°C (2 minutes) for one cycle; 94°C (30 seconds), 60°C (30 seconds), 72°C (2 minutes plus 20 seconds/cycle) for 10 cycles. The labeled products were used for CGH as described.14 Quantitative evaluation of the ratio of test and control DNA was done according to du Manoir and colleagues16 by using the Leica (Bensheim, Germany) software package Q-CGH. Five to 12 metaphases were evaluated in each experiment.
DOP-PCR
For DOP-PCR, microdissection and proteinase K digestion were performed under identical conditions as described above. After inactivation of proteinase K at 80°C for 10 minutes we used the protocol described by Speicher and colleagues5 for the primary DOP-PCR in a final volume of 50 µl. The primary DOP-PCR product was labeled in a second amplification step for 35 cycles under high stringency conditions of the DOP-PCR protocol mentioned above.
Sequence-Specific PCR
The PCRs for specific sequences and for microsatellite analysis were performed using 1.25 µl from the preamplified DNA in a final volume of 10 µl [10 mmol/L Tris-HCl, 50 mmol/L KCl, 1 mmol/L MgCl2, 0.1 mmol/L dNTP, 0.4 µmol/L each primer, 0.25 µl bovine serum albumin (20 mg/ml), and 0.5 U Taq polymerase]. The PCR reaction was run in a MJ-Research PTC-200 thermocycler programmed to 94°C (2 minutes), 58°C (30 seconds), 72°C (2 minutes) for one cycle, 94°C (15 seconds), 58°C (30 seconds), 72°C (20 seconds) for 14 cycles, 94°C (15 seconds), 58°C (30 seconds), 72°C (30 seconds), and a final extension at 72°C for 2 minutes. The results were visualized by SYBR Green (Biozym, Oldendorf, Germany)-stained 7% polyacrylamide gel electrophoresis using a Fluorimager (Molecular Dynamics, Sunnyvale, CA). Gel conditions were as described by Litt and colleagues17
The primer sequences for the test of complete MseI digestion were 5'-TCC CAG TGA CAG ATG TGA G-3' and 5'-CTT CCG GTA CAG CCT GTG-3' and are located on chromosome 17p13.3. The primer sequences used for microsatellite analysis are provided in Table 2
.
|
| Results |
|---|
|
|
|---|
|
In the first step, we assessed the minimal amount of DNA extracted from formalin-fixed tissue that is needed for successful whole genome amplification. Freshly isolated peripheral blood lymphocytes were fixed with 4% buffered formalin for 20 hours and 40 hours, because the incubation time for routine samples is not standardized but within this range. Groups of three cells were isolated by micromanipulation and subsequently subjected to the SCOMP protocol. Results were comparable to unfixed cells as tested by gene-specific PCR, in particular no difference was observed between 20 and 40 hours of formalin incubation. This indicates that the formalin fixation alone does not significantly interfere with the protocol (data not shown).
High proteinase concentrations and a long digestion time are known to be critical for high DNA yield from formalin-fixed and paraffin-embedded tissues.5
To test the effect of proteinase K incubation time before SCOMP, laser-microdissected tissue comprising an area of 48,000 µm2 (equivalent to six circles with a diameter of 100 µm each) was obtained from a 5-µm tissue section of a nonpathological lymph node that had been resected and fixed 1 month before. The samples were independently digested using 1.3 mg/ml of proteinase K for 5, 10, and 15 hours. Then we applied the SCOMP protocol and successful amplification was tested with primers for microsatellite markers located on selected MseI fragments. Because we expected longer MseI fragments to be more critical on amplification, we used primers that bind to sequences on MseI fragments of 160, 335, and 1374 bp in length. As shown in Figure 2A
, no clear difference could be observed between 5, 10, and 15 hours of digestion for the tested specific sequences. However, because the incubation time of 15 hours seemed to result in the brightest PCR bands (Figure 2A)
, this proteinase K digestion time was chosen for the subsequent experiments.
|
Because formalin-fixed DNA may be resistant to MseI restriction, thereby impeding efficient amplification, we tested whether we could detect incomplete restriction digest. For this purpose we tried to amplify a genomic sequence (318 bp) containing a MseI restriction site between the two sequence-specific primers. It was not possible to amplify the selected sequence from different amounts of formalin-fixed, MseI-restricted DNA in contrast to undigested control DNA (data not shown). Therefore, incomplete MseI digestion does not commonly occur under the applied conditions.
Amplification Method
DNA from formalin-fixed and paraffin-embedded tissue can be substantially degraded.18,19
Therefore, extensive genomic fragmentation can result in short DNA sequences that contain only one or no MseI restriction site and consequently those sequences would not be amplified by SCOMP. To rescue such DNA fragments we tested whether polishing of the overhanging DNA ends combined with blunt-end ligation of the adaptors would improve the genome amplification. This approach, here called P-SCOMP ("P" standing for polished), was compared with the standard SCOMP. The protocol used to polish the DNA ends and ligate adaptors worked well for DNA fragmented with restriction enzymes that produce 5'-protruding and -recessive ends, naturally degraded DNA from archival tissues was less efficiently amplified than that amplified by standard SCOMP (Figure 3A
and data not shown). Remarkably, SCOMP allowed the amplification of DNA from only 20 nuclei of the 7-year-old lymph node sample (Figure 3A)
.
|
Having demonstrated the suitability of SCOMP to amplify DNA that was isolated from formalin-fixed and paraffin-embedded tissues, we compared the SCOMP protocol with the most frequently applied method, the DOP-PCR. We applied DOP-PCR first to DNA that was isolated from more than 5000 cells. The obtained DOP-PCR probes hybridized well to the metaphase spreads. Then, we compared the efficiency of the DOP-PCR with SCOMP on minute, laser-microdissected tissue samples. Using DNA from 8000 µm2 no adequate hybridization signal could be obtained using DOP-PCR, which was easily achieved by SCOMP (see below). The high signal-to-noise ratio and an extensive granular hybridization of the DOP-PCR products (Figure 4A)
were incompatible with the standard settings of the evaluation software.16
In addition, the obtained CGH profile displayed the typical artifacts that are often seen when CGH with DOP-PCR products is performed, ie, excessive telomeric amplifications or losses. Finally, the failure to retrieve the correct sex of the donor underlines the insufficient sensitivity of DOP-PCR, because no significant deviation from the midline was observed although we mismatched the sex of the control DNA (Figure 4B)
.
|
Although the CGH experiments (as well as sequence-specific PCRs; not shown) proved that SCOMP is superior to DOP-PCR for the amplification of genomic DNA of less than 200 cells from formalin-fixed paraffin-embedded tissues we proceeded to determine its reliability on a single copy sequence level. Therefore, we conducted loss of heterozygosity experiments using 18 microsatellite markers mapping to four different chromosomal regions (3p13 to 3p21, 5q23 to 5q31, 16q22 to 16q23, and 17q21 to 17q22). All 18 specific PCRs were performed with the SCOMP primary PCR products. To perform these analyses we used the same DNA that we had extracted for the experiments shown in Figure 3
(ie, different cell numbers of nuclei suspension derived from normal lymph nodes of different ages). Because the selected PCR primers amplify highly polymorphic sequences, the resulting products were analyzed on a sequencing gel to discriminate between the maternal and the paternal allele. Each sequence-specific PCR can result in one of four different outcomes: 1) no amplification at all; 2) a single band is amplified in all samples of an individual patient (ie, maternal and paternal allele cannot be differentiated, the patient is noninformative for the respective marker); 3) the patient is informative, however one allele is artificially lost during PCR (mono-allelic amplification); 4) the patient is informative for the specific marker and both alleles are successfully amplified (bi-allelic amplification). Because we had noted before (Figure 2B)
that the length of the MseI fragment as well as the age of the sample influence the amplification success, the products, run on an acrylamide gel (Figure 5A
, left), were evaluated for these two factors.
|
|
Analysis of Pathological Samples
Having demonstrated the efficiency of the SCOMP protocol using genomically normal cells, we investigated laser-microdissected material from an esophageal cancer. We used a 5-year-old paraffin block of an esophageal adenocarcinoma, of which DOP-amplified DNA extracted from less than 2000 cells had not been successfully hybridized (Figure 4)
. A cell line of this primary tumor (PT1590) had previously been characterized by M-FISH.20
In addition, we could compare our results with the CGH data of the cell line PT1590 that was established from the primary tumor (Jürgen Kraus, Michael Speicher, personal communication). The smallest size of the microdissected area was set to 8000 µm2, because the amount of DNA extracted from this size had resulted in an acceptable amplification for single copy sequences in the case of the 6-year-old lymph node sample (Figure 5)
. In addition, DNA was isolated from 40,000 µm2 and from
100,000 cells. In the investigated tumor sample 8000 µm2 corresponded to
30 cells. Because primary tumors can be very heterogeneous and, in addition, are contaminated to various degrees by stromal or infiltrating cells, we expected similar, but not necessarily identical results between the different microdissected areas.
All chromosomal aberrations present in the cell line were also detected after SCOMP amplification of all microdissected areas. In particular, the data concurred in the finding of deletions at 5q, 8p, 17p, 19p, loss of the Y-chromosome, and the amplification at 17q. However, we were surprised by the extent of higher sensitivity and resolution obtained with smaller cell numbers. As can be seen from Figure 6, B and C
, chromosomal gains and losses for several loci became more pronounced and defined using small microdissected areas than using DNA from large tumor cell numbers (Figure 6D)
. For example, loss of the short arm of chromosome 17 was increasingly visible the more defined areas were used and the high-copy amplifications on 5p12-14 and 11q22-24 was only detectable in the 8000 µm2 sample.
To test whether SCOMP had been only sporadically successful using the nine samples reported, we analyzed 43 additional tumor samples. These samples were derived from three different departments of pathology (University of Hamburg, center A; city hospital Augsburg, center B; University of Munich, center C) and had been stored for 1 to 8 years. Consequently, these samples should be representative for potential variations in tissue processing and storage conditions by different laboratories in the last decade. In total, we isolated 69 areas or different numbers of nuclei from 52 paraffin blocks and applied sequence-specific PCRs or CGH after whole genome amplification (Table 1)
. PCR for D5S500 or D17S800 worked reliably with 66 of the 69 DNA samples and so far 28 from 29 samples were successfully evaluated by CGH.
| Discussion |
|---|
|
|
|---|
When we analyzed factors that might influence the DNA quality, formalin fixation alone was not found to inhibit successful amplification by SCOMP. Effective SCOMP amplification and subsequent CGH was possible with only three freshly fixed cells incubated for 20 and 40 hours in buffered formalin. Using material from routine histopathology, we first investigated the effect of prolonged proteinase K digestion and the consequences of long storage times. Digestion for 15 hours worked reliably, however higher cell numbers were needed with increasing storage age of the samples, making storage time the most important variable disturbing SCOMP. Negative effects were particularly noted for MseI fragments longer than 400 bp, suggesting substantial DNA degradation throughout time, a finding that might also explain the failure of DOP-PCR, in which primer binding is estimated to occur every 4 kb.3 Fragments of this length might rarely be present in older samples. In contrast, MseI restriction sites are present every 200 to 300 bp on average.14 To achieve amplification of degraded DNA that had lost MseI sites, we attempted to enzymatically modify the fragmented DNA. Although the polishing and amplification protocol worked well on tissue <1 year, it was less efficient with older samples than standard SCOMP. Using the latter protocol we were able to amplify the genome of 20 cells even from a 7-year-old lymph node and to successfully perform CGH. To our knowledge, this is the lowest cell number from which successful CGH was achieved with formalin-fixed tissue. Minor modifications of the original protocol14 included prolongation of the proteinase K incubation, and twice the amount of the primary PCR product for subsequent reactions. Nevertheless, only 1.25 µl of the primary PCR product are needed for a successful labeling reaction.
When the primary PCR products derived from SCOMP are used for loss of heterozygosity analysis, sample age and MseI fragment size have the highest impact on amplification success. We found, as a general rule, that older samples require microsatellite markers located on small MseI fragments. We recommend selecting informative markers on MseI fragments with a length of 400 bp and less. The exact mechanisms of DNA degradation remain unclear. It could be caused by insufficient or excessive tissue fixation, unfavorable storage conditions, or adverse variation in temperature. In addition, several factors will compromise the SCOMP reaction, such as unbuffered formalin, heat denaturation of the DNA before restriction digest, and potential inhibitors present in one of the fixation reagents. Because several factors that hamper PCR amplification have already been described, and whereas others might still be unknown, a comprehensive analysis of possible negative factors was beyond the scope of this study. Instead, the practicability of SCOMP was tested on 52 tissue blocks from three different pathology departments from Germany. Because the blocks, randomly selected from the past 8 years, were independently processed by the different routine laboratories the successful amplification by SCOMP on >90% of the samples proves the reliability and the reproducibility of the protocol.
The potential of SCOMP became fully evident when we compared the CGH results obtained from different cell numbers of the same paraffin-embedded tissue. Here, we found that the restriction to small confined tumor areas provides additional information of selected genomic aberrations. Because many unaffected chromosomes displayed equally normal CGH ratios and the high-copy amplification on 17q12 was seen in all samples, it is evident that the additional genetic alterations were blurred by clonal heterogeneity or by contaminating DNA from normal cells in the samples with increased cell numbers. This finding is particularly important, because it has been found that tumor heterogeneity is frequent in early stages of tumorigenesis.21, 22 Unraveling the evolution of early neoplastic lesions is dependent on methods that can reliably depict the diversification of different tumor cell clones within the primary lesion. SCOMP should provide a valuable tool to perform such studies.
| Acknowledgements |
|---|
| Footnotes |
|---|
Supported by the Sonderforschungsbereich (grant 456) and by the Deutsche Forschungsgemeinschaft (grant STO 464/1-1).
Accepted for publication April 15, 2002.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
V. V. Iakovlev, N. C.R. Arneson, V. Wong, C. Wang, S. Leung, G. Iakovleva, K. Warren, M. Pintilie, and S. J. Done Genomic Differences Between Pure Ductal Carcinoma In Situ of the Breast and that Associated with Invasive Disease: a Calibrated aCGH Study Clin. Cancer Res., July 15, 2008; 14(14): 4446 - 4454. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-C. Cutz, J. Guan, J. Bayani, M. Yoshimoto, H. Xue, M. Sutcliffe, J. English, J. Flint, J. LeRiche, J. Yee, et al. Establishment in Severe Combined Immunodeficiency Mice of Subrenal Capsule Xenografts and Transplantable Tumor Lines from a Variety of Primary Human Lung Cancers: Potential Models for Studying Tumor Progression-Related Changes. Clin. Cancer Res., July 1, 2006; 12(13): 4043 - 4054. [Abstract] [Full Text] [PDF] |
||||
![]() |
A A Ghazani, N C R Arneson, K Warren, and S J Done Limited tissue fixation times and whole genomic amplification do not impact array CGH profiles. J. Clin. Pathol., March 1, 2006; 59(3): 311 - 315. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. Jiang, X. Zhang, R. Deka, and L. Jin Genome amplification of single sperm using multiple displacement amplification Nucleic Acids Res., June 7, 2005; 33(10): e91 - e91. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. DeVries, S. Nyante, J. Korkola, R. Segraves, K. Nakao, D. Moore, H. Bae, M. Wilhelm, S. Hwang, and F. Waldman Array-Based Comparative Genomic Hybridization from Formalin-Fixed, Paraffin-Embedded Breast Tumors J. Mol. Diagn., February 1, 2005; 7(1): 65 - 71. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Guillaud-Bataille, A. Valent, P. Soularue, C. Perot, M.-d.-M. Inda, A. Receveur, S. Smaili, H. R. Crollius, J. Benard, A. Bernheim, et al. Detecting single DNA copy number variations in complex genomes using one nanogram of starting DNA and BAC-array CGH Nucleic Acids Res., July 29, 2004; 32(13): e112 - e112. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Wang, C. Brennan, M. Rook, J. L. Wolfe, C. Leo, L. Chin, H. Pan, W.-H. Liu, B. Price, and G. M. Makrigiorgos Balanced-PCR amplification allows unbiased identification of genomic copy changes in minute cell and tissue samples Nucleic Acids Res., May 21, 2004; 32(9): e76 - e76. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Gangnus, S. Langer, E. Breit, K. Pantel, and M. R. Speicher Genomic Profiling of Viable and Proliferative Micrometastatic Cells from Early-Stage Breast Cancer Patients Clin. Cancer Res., May 15, 2004; 10(10): 3457 - 3464. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Rook, S. M. Delach, G. Deyneko, A. Worlock, and J. L. Wolfe Whole Genome Amplification of DNA from Laser Capture-Microdissected Tissue for High-Throughput Single Nucleotide Polymorphism and Short Tandem Repeat Genotyping Am. J. Pathol., January 1, 2004; 164(1): 23 - 33. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Schmidt-Kittler, T. Ragg, A. Daskalakis, M. Granzow, A. Ahr, T. J. F. Blankenstein, M. Kaufmann, J. Diebold, H. Arnholdt, P. Muller, et al. From latent disseminated cells to overt metastasis: Genetic analysis of systemic breast cancer progression PNAS, June 24, 2003; 100(13): 7737 - 7742. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||